KNX
The KNX integration for Home Assistant allows you to connect to a KNX/IP devices.
The component requires a local KNX/IP interface like the Weinzierl 730. Through this, it will send and receive commands to and from other devices to the KNX bus.
Please note, the knx
platform does not support Windows and needs at least python version 3.5.
There is currently support for the following device types within Home Assistant:
Configuration
To use your KNX in your installation, add the following lines to your configuration.yaml
file:
knx:
Optional, recommended for large KNX installations (>100 devices) and/or if you want to use the XKNX abstraction also for other scripted tools outside of Home Assistant:
knx:
config_file: '/path/to/xknx.yaml'
- config_file (Optional): The path for XKNX configuration file.
If the auto detection of the KNX/IP device does not work you can specify ip/port of the tunneling device:
knx:
tunneling:
host: '192.168.2.23'
port: 3671
local_ip: '192.168.2.109'
- host: Host of the KNX/IP tunneling device.
- port: Port of the KNX/IP tunneling device.
- local_ip: IP of the local interface.
Explicit connection to a KNX/IP routing device:
knx:
config_file: '/path/to/xknx.yaml'
routing:
local_ip: '192.168.2.109'
- local_ip: The local IP address of interface (which should be used for multicasting).
knx:
fire_event: True
fire_event_filter: ["1/0/*", "6/2,3,4-6/*"]
- fire_event (Optional): If set to True, platform will write all received KNX messages to event bus
- fire_event_filter (Optional): If
fire_event
is setfire_event_filter
has to be specified.fire_event_filter
defines a list of patterns for filtering KNX addresses. Only telegrams which match this pattern are sent to the HOme Assistant event bus. - state_updater (Optional): The component will collect the current state of each configured device from the KNX bus to display it correctly within Home-Assistant. Set this option to False to prevent this behavior.
Services
In order to directly interact with the KNX bus, you can now use the following service:
Domain: knx
Service: send
Service Data: {"address": "1/0/15", "payload": 0}
- address: KNX group address
- payload: Payload, either an integer or an array of integers
Exposing sensor values or time to knx bus
KNX component is able to expose time or sensor values to KNX bus. The component will broadcast any change of the exposed value to the KNX bus and answer read requests to the specified group address:
# Example configuration.yaml entry
knx:
expose::
- type: 'temperature'
entity_id: 'sensor.owm_temperature'
address: '0/0/2'
- type: 'time'
address: '0/0/1'
- type: 'datetime'
address: '0/0/23'
- type: Type of the exposed value. Either time or datetime or any supported type of KNX Sensor (e.g. “temperature” or “humidity”).
- entity_id: Entity id of the HASS component to be exposed. Not necessarry for types time and datetime.
- address: KNX group address.
Known issues
Due to lame multicast support the routing abstraction and the gateway scanner only work with Python >=3.5.