Min/max Sensor
The min_max
sensor platform consumes the state from other sensors to determine the minimum, maximum, latest (last) and the mean of the collected states. The sensor will always show you the lowest/highest/latest value which was received from all monitored sensors. If you have spikes in your values, it’s recommended to filter/equalize your values with a statistics sensor first.
This sensor is an alternative to the template sensor’s value_template:
to get the average of multiple sensors.
{{ ((float(states.sensor.kitchen_temperature.state) +
float(states.sensor.living_room_temperature.state) +
float(states.sensor.office_temperature.state)) / 3) | round(2)
}}
Sensors with an unknown state will be ignored in the calculation. If the unit of measurement of the sensors differs, the min_max
sensor will go to an error state where the value is UNKNOWN
and unit of measurement is ERR
.
To enable the min_max
sensor, add the following lines to your configuration.yaml
:
# Example configuration.yaml entry
sensor:
- platform: min_max
entity_ids:
- sensor.kitchen_temperature
- sensor.living_room_temperature
- sensor.office_temperature
Configuration variables:
- entity_ids (Required): At least two entities to monitor. The unit of measurement of the first entry will be the one that’s used. All entities must use the same unit of measurement.
- type (Optional): The type of sensor:
min
,max
,last
ormean
. Defaults tomax
. - name (Optional): Name of the sensor to use in the frontend.
- round_digits (Optional): Round mean value to specified number of digits. Defaults to 2.