NUT Sensor


The nut sensor platform allows you to monitor a UPS (battery backup) by using data from a NUT (Network UPS Tools) server.

To use this sensor platform, you need to add the following to your configuration.yaml file:

# Example configuration.yaml entry
sensor:
  - platform: nut
    resources:
      - ups.load
      - ups.realpower.nominal
      - input.voltage
      - battery.runtime

Configuration variables:

  • name (Optional): Name prefix for defined sensors. Defaults to ‘NUT UPS’.
  • host (Optional): The host name or address of the device that is running NUT. Defaults to localhost.
  • port (Optional): The port number. Defaults to 3493.
  • alias (Optional): Name of the ups on the NUT server. Will default to the first UPS name listed.
  • username (Optional): Username to login to the NUT server. Default is none.
  • password (Optional): Password to login to the NUT server. Default is none.
  • resources array (Required): Contains all entries to display.

Example

Given the following example output from NUT (Your variables may differ):

'ups.timer.reboot': '0', 
'battery.voltage': '27.0', 
'ups.firmware.aux': 'L3 -P ', 
'ups.mfr': 'American Power Conversion', 
'battery.runtime.low': '120', 
'ups.delay.shutdown': '20', 
'ups.load': '19', 
'ups.realpower.nominal': '600', 
'battery.charge.warning': '50', 
'battery.charge.low': '10', 
'ups.vendorid': '051d', 
'ups.timer.shutdown': '-1', 
'ups.test.result': 'No test initiated', 
'ups.firmware': '868.L3 -P.D', 
'battery.mfr.date': '2015/05/08', 
'ups.serial': '3B1519X19994  ', 
'ups.productid': '0002', 
'battery.runtime': '2552', 
'battery.date': '2001/09/25', 
'battery.voltage.nominal': '24.0', 
'battery.type': 'PbAc', 
'ups.mfr.date': '2015/05/08', 
'ups.status': 'OL', 
'ups.model': 'Back-UPS RS1000G', 
'ups.beeper.status': 'disabled', 
'battery.charge': '100', 
'input.sensitivity': 'medium', 
'input.transfer.low': '88'
'input.transfer.high': '147', 
'input.voltage': '121.0', 
'input.voltage.nominal': '120', 
'input.transfer.reason': 'input voltage out of range', 

Use the values from the left hand column. Support is included for most values with ‘ups’, ‘battery’, and ‘input’ prefixes.

sensor:
  - platform: nut
    name: UPS Name
    host: 192.168.11.5
    port: 3493
    alias: ups_name
    username: user
    password: pass
    resources:
      - ups.load
      - ups.realpower.nominal
      - input.voltage
      - battery.runtime